*detectandcreateface2facecontacts
Detects if the specified components are within the contact distance specified and creates contact entities relevant to the solver interface.
Syntax
*detectandcreateface2facecontacts input_entity_type mark_id tolerance reverse_angle use_shell_thickness consolidate_surfaces run_intersection_check contact_type master_entity_type slave_entity_type property_option contact_property_id static_friction_value contact_material_id contact_master_sensor_id contact_slave_sensor_id skip_preview
Type
HyperMesh Tcl Modify
Description
Detects if the specified components are within the contact distance specified and creates contact entities relevant to the solver interface.
The current solver template is used as an implicit input.
The output contact entities are created specific to a supported solver. For example, in ANSYS it will create contact surfaces and groups whereas in OptiStruct it will create groups with card images.
This is supported for ANSYS, OptiStruct, Samcef and Nastran (MSC).
Inputs
- input_entity_type
- The input entity type. Must be set to comps.
- mark_id
- The ID of the mark containing the input entities. Valid values are 1 and 2.
- tolerance
- A non-zero search distance specified as the vicinity within which the contact is to be detected by executing the penetration collision logic. Components spaced greater than the vicinity tolerance are not considered to be in contact.
- reverse_angle
- The angle value used to compute the extent of the contact surface. This parameter is used in detecting the span of a convex contact surface on non-planar surfaces.
- use_shell_thickness
- A flag to use element thickness values specified on shell elements as the search distance. When this flag is specified as 1, then tolerance is ignored or can be 0.
- consolidate_surfaces
- After the contact is detected, contact surfaces are created. Those contact surfaces can be on different topological locations (discontinuous) on the base component that is in contact with that particular target component. When set as 0, a contact surface for each discontinuous patch is created and updated in the contact group. If set as 1, then only 1 contact surface is created for all the discontinuous patches.
- run_intersection_check
- Before a contact is detected and established using the penetration algorithm, the user has the option to execute the intersection check between any two components for the same input parameters of tolerance and reverse_angle by setting this as 1. Intersection is detected even if one element on the source component physically intersects an element on the target component. In such cases the contact surface normal is not uniquely defined for those intersecting elements.
- contact_type
- The type of contact to create. The following values are supported:
Solver Value Type OptiStruct 0 Contact 1 Tie Samcef 0 MCT 1 STI - master_entity_type
- The master entity type. The following values are supported:
Solver Value Type OptiStruct 0 (default) SET_ELEM 1 SURF - slave_entity_type
- The slave entity type. The following values are supported:
Solver contact_type Value Type OptiStruct all 0 SET_GRID 1 SET_ELEM 2 SURF Samcef 0 (MCT) 0 SET of elements (2D) CONTACT SURFACE (3D)
1 SET of nodes (2D) SET of face nodes (3D)
- property_option
- The property option. The following values are supported:
Solver contact_type Value Type ANSYS N/A 0 Existing property ID is used 1 Infer sensors and auto-generate properties OptiStruct 0 (Contact) 0 SLIDE 1 STICK 2 FREEZE Nastran (MSC) N/A <prop_id> Geometric contact property ID (BCGPIC) - contact_property_id
- On creation of contact pairs, some of the interfaces have attributes to select property ID as the input. When this argument is specified with an ID, and if it exists, it is attached to the contact pair. For non-relevant interfaces this will be ignored.
- static_friction_value
- The value for the static friction coefficient. This is superseded by contact_property_id and property_option arguments. If contact_property_id, property_option and static_friction_value are all specified, contact_property_id takes precedence. If property_option and static_friction_value are both specified, property_option takes precedence. In both cases, the friction value is adjusted internally to a negative number to establish precedence and thus will be ignored.
- contact_material_id
- On creation of contact pairs, some of the interfaces have attributes to select material ID as the input. When this argument is specified with such an ID, and if it exists, it is attached to the contact pair. For non-relevant interfaces this will be ignored.
- contact_master_sensor_id
- On creation of contact pairs, some of the interfaces have attributes to select master sensor ID as the input. When this argument is specified with such an ID, and if it exists, it is attached to the contact pair. For non-relevant interfaces this will be ignored. In ANSYS, property_option is ignored when specified along with this option.
- contact_slave_sensor_id
- On creation of contact pairs, some of the interfaces have attributes to select slave sensor ID as the input. When this argument is specified with such an ID, and if it exists, it is attached to the contact pair. For non-relevant interfaces this will be ignored. In ANSYS, property_option is ignored when specified along with this option.
- skip_preview
- After creation of contact entities, by default (0), all the newly created contact entities are considered to be "under review” and their export flag is turned off. If you choose to confirm all the auto-contact created entities and have their export flag turned on, this should be 1. When specified as 1, a confirmation dialog box with the entities list is also skipped.
Examples
To detect contacts between all components in the model:
hm_createmark comps 1 "advanced" "all"
*detectandcreateface2facecontacts components 1 1.0 15.0
*detectandcreateface2facecontacts components 1 0 15.0 1
*detectandcreateface2facecontacts components 1 1.0 15.0 0 0 1 0 0 0 0 1 0 2 3 4
*detectandcreateface2facecontacts components 1 5 15 0 1 1 0 1 2 0 0 0.18
*detectandcreateface2facecontacts components 1 5 15 0 1 1 0 0 1 1
Errors
if { [ catch {command_name...} ] } {
# Handle error
}
Version History
14.0.130