*CE_ProjectionCheck
Check quality of projections with connectors.
Syntax
*CE_ProjectionCheck ce_inmark ce_outmark length_flag length tolerance sel_type future1 future2 future3
Type
HyperMesh Tcl Modify
Description
Check quality of projections with connectors.
Inputs
- ce_inmark
- Mark including connectors to be checked.
- ce_outmark
- Mark including failed connectors.
- length_flag
- 0 - Use T1+T2/2 as checking length.
- length
- The value of checking length, only be used when length_flag =1.
- length_tol
- The allowable variation in projection length compared to the value for length.
- checking_type
- 0 - Check too long.
- future1
- Not presently used.
- future2
- Not presently used.
- future3
- Not presently used.
Examples
*createmark connectors 1 all
*CE_ProjectionCheck 1 2 1 10.0 0.2 0 0 0 0
hm_getmark connectors 2
Errors
if { [ catch {command_name...} ] } {
# Handle error
}
Version History
9.0