Configuration Window
In the Browser Configuration dialog you can select which columns to display in the browser, and change the way special tools, such as find twin connectors, operate.
Open the Browser Configuration dialog by right-clicking in the Connector Entity Browser and selecting Configure Browser from the context menu.
Local Options
- Show Link Rule Columns
- When enabled, each link displays its reconnection rule (use ID, use
name, or at fe realize) via the Rule column. The reconnect rule is set
when the connector is created, and determines what the connector will
automatically try to reconnect with when a part is deleted and then
replaced.
- If the new part has the same part ID as the deleted one, then use ID will automatically reconnect.
- If the new part has the same name as the deleted one, then use name will automatically reconnect.
- Show Link Structure Columns
- When enabled, each link displays its link state (connect to mesh or geometry) via the Structure column.
- Max Link Column Viewed
- Regardless of how many links a connector might have, the browser will only display the specified number of columns.
- Show Primary Links Only
- By default, both primary and secondary links are displayed in the browser. To only display primary links, select the Show Primary link only checkbox.
- Automatic Filter
- Filter the link entity list and the connector list simultaneously when performing a show, isolate, or find operation.
- Consider Geometry
- Consider geometry along with elements while using Show/Hide/Isolate operations.
- Consider HAZ Elements
- Consider HAZ elements while using Show/Hide/Isolate operations. When this option is on, and if connectors are isolated, HAZ elements are also isolated along with connectors and their links.
- Find Twin Connectors
- Select how two connectors are found:
- Minimum two links
- Find only the connectors that have two or more matching links.
- Exact links
- Find only the connectors that have the same links. For example, if you start with a connector that has two links, than another connector with three links will not be found even if its first two links matched.
- Find Connectors Between With
- Select how connectors between selected links are found:
- Minimum two selected links
- Only connectors that link to at least two selected entities will be affected. Connectors with only one link to any of the selected entities will be ignored.
- Exact selected links
- Only connectors that link to the selected entities will be affected. This can vary from the Minimum two selected links option, because connectors with three or more links which link two selected entities with at least one unselected entity, would still be found by the Minimum two selected links option but not by this one.
- All selected links
- Any connector shared by the selected entities will be
found.Note: Connectors which link selected entities to any unselected ones will not be found, as they are not located between the selected entities.
- Filter Links To
- Choose which links to filter when performing search/isolation
functions.
- Projection Components
- Isolate the entire link component.
- Projection Elements
- Isolate only the elements on which a projection falls.
- Projection and Attached Elements
- Isolate only the elements on which the projection falls and the elements which the connector FE connects.
Global Options
- Autofit
- Use this option in combination with the other view option toggle buttons and show, hide, isolate, or isolate only, or in combination with the advanced action buttons. After an action is performed, the newly found connectors and/or entities are placed in the middle of the screen. If this option is used in combination with one of the previously mentioned buttons, it works like a pure fit view.
- Autocolor Visualization Mode
- Automatically switch the element color mode when accessing different tabs in the Connector Link Entity Browser.