intersection

Configurations for the intersection check functionality.

GUI Default Settings

tolerance
Depth of the intersection to be filtered. Intersection less than this value will not be reported in the PowerPoint.


Default/Allowed: 0.1 to 1.0 mm
slide-number
The starting number is shown in right top corner of PowerPoint file.


Default/Allowed: 1 to 10000
report
Initial directory for report output path.
Default/Allowed: C:/temp
action
User action type to be executed.
Check
Only intersection check will be executed, no reports.
Report
Only Reports will be generated from the previous check
Both
Check and Report generation will be executed in a sequence.
Default/Allowed: Check, Report or Both
mode
Default opitons for Run type.
interactive
Check executed in the front ground HyperMesh session
background
Check executed in the background HyperMesh sessions, automatic restart executed, if errors occur, the errors will be displayed in the browser as "Crash" keyword.
Default/Allowed: interactive or background
logic
Algorithm used for the checks.
allcomp
All parts will be imported, and check will be executed. Faster than “loop” logic but it requires good PC hardware.
loop
Two part will be imported at once and check will be executed, very slow but with less memory full model can be checked.
subsystem
Checks are executed across two subsystems, if two or more subsystems are selected from the tree or selected via assembly-level option. All parts will be checked, if one sub-assembly is selected from tree or assembly-level is 0.
Default/Allowed: allcomp, loop or subsystem
Clearance_Zone (CL)
Clearance value will be assigned on the CAD data during the intersection check. Half of the value will be assigned on each side of the CAD data. Increasing the value might increase the execution time.


Default/Allowed: 0.0. to 5.0 mm

Filter Settings

revision-check
New revisioned CAD data and its surrounding CAD data will be checked for intersection, if this option is ON. All the CAD parts irrespective of revision will be checked, if this option is turned OFF.
Default/Allowed: ON or OFF
revision-folder
Initial directory for selecting the revision CAD data. File name is compared against files in the selected folder and CAD files will be replaced and revision flag is ON for that part.
Default/Allowed: C:/temp
body-type
Special treatment based on the name.
METAL-METAL
All the parts inside the METAL folder will be checked.
TRIM-TRIM
All the parts inside the TRIM folder will be checked.
METAL-TRIM
Parts across METAL and TRIM folder will be checked. No check will be executed inside the METAL or TRIM folders.
Default/Allowed: METAL-METAL, TRIM-TRIM or METAL-TRIM
Max-number-solids
Parts will not be considered for the check, if the number of solid CAD inside a part exceeds this number. This is done to avoid check on solid spot welds or harness cables.
Default/Allowed: 2 to 150
loopLimit
Each time two parts will be compared if the value is 0. If more than 0, parts (specified # of parts) are loaded at once in one HyperMesh session and comparison will be executed.
Default/Allowed: 0 to 1000
min-areapercent
Minimum area of part that must be considered for the check. Area of the part less than this will be ignored in the check. This is implemented to avoid small parts that do not have proper Name or Part Number.
Default/Allowed: 1.0 to 1000.0 mm square
min-Diagonal-BBox
Minimum bounding box diagonal length of part that must be considered for the check. Diagonal length of the part less than this will be ignored in the check. This is implemented to avoid small parts that do not have proper Name or Part Number.
Default/Allowed: 1.0 to 10.0 mm
bbox-view
Bounding boxes for each part are displayed in the HyperMesh graphics for reference after the check and report is done. You can check if both of CAD or FE is at same place or same size.
Grey box
Indicates # CPUs
Green box
Indicates bounding box of the parts.


Default/Allowed: ON or OFF