The layer filter reduces the layer list available in the Contour, Iso, Vector, and Tensor panels for the data types that
have layers (for example, plies in composite stress/stains or any tensor result with layers).
After a contour plot has been applied in the Contour panel, the Cache feature will become active and allow you to add
the currently active contour result to an internal cache.
The averaging options allow you to limit the averaging of results to only a group of elements that are considered to be
bound by same feature angle or face.
The Free Body Diagram (FBD) tool facilitates the extraction and post-processing of Grid Point Force (GPFORCE) results
and can be used create and edit Free Body Diagrams (FBD).
Stress linearization, a widely used procedure in the Oil and Gas and ship-building industries, is used to analyze stresses
in a structure, such as a pressure vessel.
A result manipulation library that enables user-defined data types to be added to a result, and transitions complex data
manipulation tasks from HyperView to a reusable, modifiable set of libraries that focus solely on result processing tasks.
The fatigue manager allows you to write stress and strain results from a finite element analysis to an external file that
can be used to set up a fatigue analysis.
The Count layers option in the Contour panel and Iso panel allows you to calculate and
display how many layers/plies are in each element.
When used with a Value Filter, the Count aggregation mode will return the number of
layers that meet the specified criteria. This can be a useful tool when trying to determine
how many layers/plies are failing or exceeding certain threshold criteria.
The Count option can be used in conjunction with the Layer filter and the Value
filter options (located in the middle of the panel), in order to further specify or define
the plies/layers to be included in the count results (see the examples below).
The tables below illustrate how the Count option and the Value Filter work
together:
All layers are included in the count and other calculations (Max, Min,
etc.).
Only the layers which are less than or equal to 0.4 (the Value filter setting) are
included in the count and other calculations (Max, Min, etc.).
Only the layers which are greater than or equal to 0.4 (the Value filter setting) are
included in the count and other calculations (Max, Min, etc.).
Only layers 1, 3, and 5 (selected using the Layer filter) which are greater than or
equal to 0.4 (the Value filter setting) and are included in the count and other calculations
(Max, Min, etc.).