poISystemCtrl SetLayer

Sets the current layer for the ply system review.

Syntax

sysctrl_handle SetLayerlayer_name

Application

HyperView Tcl Modify

Description

This command sets the layer to be applied for a ply system review plot (for example - Ply 1, Ply 10001001, etc.). In the case of an element and material system review plot, this command will be ignored. If the layer name contains spaces. the name must be specified inside double quotes (for example - “Ply 1”). The layer name must exist in the list of available layers. You can get this list from the result control by using the GetLayerList command.

Inputs

layer_name
The name of the layer to be set.

Example

To set the layer in a system review plot to “Ply 3” for a model containing the layer list {“Ply 1” “Ply 2” “Ply 3”}:
hwi OpenStack
hwi GetSessionHandle session_handle
session_handle GetProjectHandle project_handle
project_handle GetPageHandle page_handle [project_handle GetActivePage]
page_handle GetWindowHandle window_handle [page_handle GetActiveWindow]
window_handle GetClientHandle client_handle
client_handle GetModelHandle model_handle [client_handle GetActiveModel]
model_handle GetResultCtrlHandle result_handle
result_handle GetSystemCtrlHandle sysctrl_handle
sysctrl_handle SetLayer ”Ply 3”
hwi CloseStack

Errors

Always returns success even if the layer name does not exist in the available layer list. In the case of an invalid layer, the command will be ignored. If no results were attached, the contour handle is not retrievable, thus this command cannot be called.