poISymmetry SetOrder

Sets the sequence of the various symmetry operations.

Syntax

sym_handle SetOrdercode

Application

HyperView Tcl Modify

Description

This command sets the sequence of the various symmetry operation like reflect, rectangular copy, and circular copy.

Inputs

code
The integer value which controls the sequence of the various symmetry operations. See the list below for the possible values and meaning of each code:
0
mirror, rect pattern, circ pattern
1
mirror, circ pattern, rect pattern
2
rect pattern, mirror, circ pattern
3
rect pattern, circ pattern, mirror
4
circ pattern, rect pattern, mirror
5
circ pattern, mirror, rect pattern

Example

To get the sequence of the symmetry operation:
hwi OpenStack
hwi GetSessionHandle session_handle
session_handle GetProjectHandle project_handle
project_handle GetPageHandle page_handle [project_handle GetActivePage]
page_handle GetWindowHandle window_handle [page_handle GetActiveWindow]
window_handle GetClientHandle client_handle
client_handle GetModelHandle model_handle [client_handle GetActiveModel]
model_handle GetSymmetryCtrlHandle sym_handle

sym_handle SetOrder 0    # First mirror, then rect copy and then circular copy
sym_handle SetOrder 5    # First circular copy, then mirror and then rect copy

hwi CloseStack

Errors