The Altair GUI Toolkit is a resource tool for coding Tcl/Tk dialogs. It contains documentation of the HyperWorks commands, demo pages that illustrate our Altair GUI standards, and sample code for creating those examples.
The Model Identification Tool, known as HyperWorks, is a profile in HyperGraph for fitting test data from frequency- and amplitude-dependent bushings to analytical models. The HyperWorks operates in conjunction with HyperGraph, MotionView and MotionSolve to provide you with a comprehensive solution for modeling and analysis.
The Altair Bushing Model is a library of sophisticated, frequency- and amplitude-dependent bushing models that you can use for
accurate vehicle dynamics, durability and NVH simulations. The Altair Bushing Model supports both rubber bushings and hydromounts.
This section provides information about using the Altair Bushing Model, also known as AutoBushFD, with MotionView. The Altair Bushing Model is a sophisticated model that you can use to simulate the behavior of bushings in vehicle
dynamics, durability and NVH simulations.
The Model Identification Tool (HyperWorks) is a utility in HyperGraph that you use to fit experimental data to various bushing models. The HyperWorks generates a General Bushing System file, .gbs file, which defines the bushing properties.
You can add an Altair Bushing Model, also known as AutoBushFD, a frequency-dependent bushing, to your MotionView model using the Add Auto Entity tool in MotionView.
The friction torque resists rotation of the bodies relative to one another. The friction model supports stiction and
sliding effects as well as a measured friction torque due to preload in the bushing.
Use Mount Stiffness when you want to approximate the structural deflection of the bodies that the bushing connects
due to the load that the bushing carries. Mount stiffness is modeled as a set of linear springs and dampers in series
with the bushing stiffness and damping, thus softening the connection between the bodies. Alternatively, you can use
flexible bodies to model the bodies the bushing connects.
You can activate Mount Limits to simulate material contact between the bodies that the bushing connects. This contact
limits the bushing deflection. When the deflection is sufficient in a given direction to close the gap distance, the
mount limit forces or torques become active. The forces and torque are computed using an impact function. An exponent
greater than one (1) provides increasing stiffness with penetration. The damping force is smoothed with a cubic step
function over the penetration distance.
In addition to adding a single bushing to your project, you can also add a pair of bushings such as AutoBushFD pair.
When you add a pair, MotionView automatically reflects modifications you make on the left bushing of the pair to the right bushing, unless you choose
otherwise. MotionView assumes bilateral symmetry about the global X-Z plane.
HgTrans translates solver results files from their native file format to Altair Binary Format (ABF). This can be done using
the HgTrans GUI or via the HgTrans batch mode.
The HyperWorks Automation Toolkit (HWAT) is a collection of functions and widgets that allows an application to quickly assemble
HyperWorks automations with minimal effort and maximum portability.
HyperWorks Verification and Validation Harness (HVVH) is a tool that can be used to verify and validate HyperWorks products. End users can use this tool to quickly evaluate the software quality, performance, reliability,
scalability, and robustness, and to gain more confidence in HyperWorks products.
Uninstall HyperWorks is a tool to launch the HyperWorks uninstallation program. This program contains two options that allow you to either remove the originally installed
files, or remove all the files that resides in the installation directory.
The Model Identification Tool, known as HyperWorks, is a profile in HyperGraph for fitting test data from frequency- and amplitude-dependent bushings to analytical models. The HyperWorks operates in conjunction with HyperGraph, MotionView and MotionSolve to provide you with a comprehensive solution for modeling and analysis.
This section provides information about using the Altair Bushing Model, also known as AutoBushFD, with MotionView. The Altair Bushing Model is a sophisticated model that you can use to simulate the behavior of bushings in vehicle
dynamics, durability and NVH simulations.
You can activate Mount Limits to simulate material contact between the bodies that the bushing connects. This contact
limits the bushing deflection. When the deflection is sufficient in a given direction to close the gap distance, the
mount limit forces or torques become active. The forces and torque are computed using an impact function. An exponent
greater than one (1) provides increasing stiffness with penetration. The damping force is smoothed with a cubic step
function over the penetration distance.
You can activate Mount Limits to simulate material contact between the bodies that
the bushing connects. This contact limits the bushing deflection. When the deflection is
sufficient in a given direction to close the gap distance, the mount limit forces or torques
become active. The forces and torque are computed using an impact function. An exponent
greater than one (1) provides increasing stiffness with penetration. The damping force is
smoothed with a cubic step function over the penetration distance.
The figure below illustrates the concept of positive and negative gap for mount
limits in a bushing:
Click Activate to enable the options.
For Gap, enter a positive real value giving the bushing
deflection where the bodies contact. The limit force or torque is zero until the
bushing deflection closes the corresponding gap. The dimension is length.
For Stiffness, enter a positive real value giving the
limit stiffness for the given direction.
Note: Translation dimensions are force and length-1. Rotational
dimensions are force, length, and angle-1.
In the Exponent field, enter a positive real value
giving the power penetration is raised to. An exponent greater than one (1.0)
gives increasing stiffness with penetration.
For Damping, enter a positive, real value for the
damping coefficient.
Note: Translation dimensions are force, time, and length-1.
Rotational dimensions are force, length, time, and
angle-1.
For Penetration, enter a positive, real value giving the
penetration at which the damping is fully effective. Damping forces and torques
are smoothed by cubic step function over the penetration to prevent
discontinuity of the damping force or torque. The dimension is length.